產(chǎn)品規(guī)格書
1. 安規(guī)標準 / SAFETY STANDARD
電源符合下列的國際標準:
The green mode switching power supply shall be certified by the following international regulatory standards:
Country | Certified Status | 標準 | |
Standard | |||
GS | 歐洲 | MEET | EN61347-1,/-2-13 |
Europe | |||
CE | 歐洲 | MEET | EN61347-1,/-2-13 |
Europe | |||
UL | 美國 | MEET | UL 8750+UL60950 |
USA | |||
CUL | 加拿大 | MEET | UL 8750+UL60950 |
Canada | |||
- | 歐洲 | MEET | 藍色天使( Blue Angel) |
Europe | |||
- | 美國 | MEET | 能源之星(Energy start) |
USA |
2. 輸入特性 / INPUT FEATURE
2.1 輸入電壓范圍/INPUT VOLTAGE RANGE:90Vac to 264Vac
2.2 額定輸入電壓/RATED INPUT VOLTAGE: 100Vac to 240Vac
2.3 輸入頻率范圍/INPUT FREQUENCY RANGE: 47Hz to 63Hz
2.4 額定工作頻率/RATED INPUT FREQUENCY: 50Hz/60Hz
2.5 輸入100Vac條件額定負載時最大輸入電流不超過0.5A.
INPUT CURRENT:0.5A max.&100Vac.
2.6 在冷開機條件下,最大浪涌電流不超過 30A (輸入100-240Vac額定負載時).
INRUSH CURRENT: 30A max. at 100-240Vac input for a cold start at 25oC.
2.7 效率:>83% (輸入100-240Vac和輸出滿載條件).
EFFICIENCY: higher than 83% at 100-240Vac input and output full load(2.5A).
3. 輸出特性 / OUTPUT FEATURE
額定輸出電壓: 12.0VDC | 規(guī)格限定/SPEC. LIMIT | |
RATED OUTPUT VOLTAGE | Min. value | Max. value |
空載輸出電壓 | 11.4VDC | 12.6VDC |
Unload output regulation | ||
負載輸出電壓 | 11.4 VDC | 12.6 VDC |
Rated load output voltage | ||
額定輸出電流 | 0.0 A | 2.5A |
Rated output current | ||
短路輸出功率 | Hiccup mode | |
Short-circuit output power | hiccup(3W) | |
電壓調(diào)整率 | ≤1% | |
Line regulation | ||
負載調(diào)整率 | ≤5% | |
Load regulation | ||
輸出紋波及噪聲/Ripple and Noise | ≤100 mVp-p. | |
(20MHz Bandwidth 10uF Ele.Cap. & 0.1uF Cer. Cap.) | ||
輸出瞬態(tài)響應/Transient response | ≤350mV | |
(Output load change from 20% to 80% of full load(2.5A)) |
4. 保護特性 / PROTECTION FEATURE
4.1 過電流保護: 當輸出達到其過流保護觸發(fā)點時(過流點設定為最大負載電流的120-300%,且過流狀態(tài)下輸入功率恒定),電源將進入打嗝模式保護狀態(tài),當過載故障被解除后,電源能自動恢復到正常輸出.
OVER - CURRENT PROTECTION: The power supply shall be hiccupped and no damage shall occur when output current reaches to its over-current protection trigger point (set@ Max load 120-300% ). The power supply shall be self - recovery when the fault condition is removed.
4.2 輸出短路保護:在任何時候,任何輸入條件下,當輸出遇到在短路情況下,電源供應器會進入打嗝模式保護狀態(tài),當故障解除后,電源能自動恢復正常輸出.
SHORT - CIRCUIT PROTECTION: The power supply shall be hiccupped(input power less than 3W) and no damage shall occur when any output operating in a short circuit condition under any line condition for an indefinite period of time. The power supply shall be self - recovery when the fault condition is removed.
4.3 過電壓保護: 當輸出達到其過壓保護觸發(fā)點時(過壓點設定為最大輸出電壓的120-180%,且過壓狀
態(tài)下輸入功率恒定),電源進入打嗝模式保護狀態(tài),當故障解除后,電源能自動恢復正常輸出.
OVER - VOLTAGE PROTECTION: The power supply shall be hiccupped and no damage shall occur when output current reaches to its over- voltage protection trigger point (set@ Max output voltage 120-180% ). The power supply shall be self - voltage when the fault condition is removed.
5. 環(huán)境條件 / ENVIRONMENTAL CONDITIIONS
5.1 操作條件: 在下列環(huán)境條件下,電源供應器能夠連續(xù)工作在各種模式,且不會造成性能的退化.
OPERATING: The power supply shall be capable of operating continuously in any mode without performance deterioration in the following environmental conditions.
5.1.1 環(huán)境溫度: 0℃~40℃
Ambient Temperature: 0℃~40℃
5.1.2 相對濕度: 10%~90%
Relative Humidity: 10%~90%
5.1.3 Vibration: 1.0mm, 10–25Hz, 15 minutes per cycle for each axis (X, Y, Z)
5.2 非操作條件: 電源供應器能夠長期的經(jīng)受下列的環(huán)境條件,且不允許有電氣及機械方面的損傷和幷發(fā)工作的缺陷.
NON-OPERATING: The power supply shall be capable of withstanding the following environmental conditions extended periods of time, without sustaining electrical or mechanical damage and subsequent operational deficiencies
5.2.1 環(huán)境溫度: -30℃~70℃
Ambient Temperature: -30℃~70℃
5.2.2 相對濕度: 10%~90%
Relative Humidity: 10%~90%
5.2.3 振動和沖擊: 電源供應器裝配及出貨的包裝設計,均能承受正常運輸?shù)恼駝? 并符合
MIL–STD-810D 方法 514 和程序 X.
Vibration and Shock :The power supply shall be designed to withstand normal transportation vibration per MIL–STD-810D, method 514 and procedures X, as it is mounted in the chassis assembly and packed for shipping.
5.2.4 跌落試驗:電源產(chǎn)品能在裝運過程中,由于意外跌落之地面及水泥地(最高1.55M) 落下順序為三菱六面且不允許有電氣及機械方面的損傷和幷發(fā)工作的缺陷.
Drop Test :Power supply product can in transport process, because the accident drops into its ground and cement ground( tallest 1.55 Ms)s fall in in proper order for Mitsubishi six,without sustaining electrical or mechanical damage and subsequent operational deficiencies
6. 電磁兼容性標準 / EMC STANDARDS
6.1 EMI 標準/ EMI STANDARDS
本電源供應器符合輻射及傳導之限定要求,滿足FCC PART15B CLASS B,EN EN55015
The power supply met the radiated and conducted emission requirements requirements for
FCC PART15B CLASS B, EN55015,
7. 可靠性及品質(zhì)控制 / RELIABILITY AND QUALITY CONTROL
7.1 老化: 電源在35℃±5℃ 和滿載條件下老化 8 小時.
BURN-IN: The power supply shall under go a minimum of 8 hours Burn-In test under full load at 35℃±5℃.
7.2 元件溫度要求:半導體結(jié)溫不允許超過其制造商要求的最大溫度值.
COMPONENT DERATING: Semiconductor junction temperatures shall not exceed the manufacturer’s maximum thermal rating.
7.3 平均故障間隔時間: 在25℃條件下,電源供應器在規(guī)格限定內(nèi)工作,其MTBF最少要 50,000 小時.
MTBF: When the power supply is operating within the limits of this specification the MTBF shall be at least 50,000 hours at 25℃ (MIL-STD-217F).
8. 絕緣介電強度(耐壓)/ DIELECTRIC WITHSTANDING STRENGTH (HI-POT)
輸入對輸出端、輸入對殼體之間施加3000V交流電壓測試1分鐘(漏電流≤5mA),無擊穿或飛弧現(xiàn)象。(量產(chǎn)測試用3秒鐘).
Primary to Secondary & Case AC3000V, 1 minute(leakage current less than5mA) for type test, (3 second for production).
9. 絕緣阻抗 / INSULATION RESISTANCE
輸入對輸出絕緣阻抗用500VDC測試時不小于 50 兆歐姆.
Input to output: no less than 50 MOHM(500VDC)
10. 漏電流 / LEAKAGE CURRENT
當電源供應器工作在最大輸入及最大負載情況下,其漏電流小于 0.25 mA, 滿足Class ‖等級.
The leakage current shall be less than 0.25 mA for Class ‖ when power supply is operated maximum input voltage and maximum load.
11. 主要測量設備 / MAJOR MEASURE EQUIPMENT
11.1 交流輸入電源/ AC SOURCE: CHROMA 61602
11.2 電源功率計/ POWER METER: PF9800
11.3 電子負載/ ELECTRONIC LOAD: CHROMA 6312
11.4 示波器/ OSCILLOSCOPE: Tektronix TDS 1012
11.5 萬用表/ MULTIMETER: Fluke 45
11.6 直流輸入電源/ DC POWER: TPR-3003-2D
11.7 耐壓測試儀/ HI-POT TESTER:GOODWILL GPT-605
11.8 多路溫度測試儀: 威格DWC2515
11.9 冷熱交變箱: TERCHY MHU-1000A
12. 光電參數(shù)/Parameters
產(chǎn)品編碼 (Part No) |
輸入電壓(V AC) |
額定電流 (mA) |
電源效率(Efficiency) |
額定電壓 (V DC) |
尺寸(mm) |
額定功率 (W/piece) |
SL-18-12 |
100-240 |
1.5A |
≥85% |
12V DC |
220*18*14.5 |
12W |
SL-24-12 |
100-240 |
2A |
≥85% |
12V DC |
220*18*14.5 |
24W |
SL-36-12 |
100-240 |
3A |
≥85% |
12V DC |
300*18*14.5 |
36W |
SL-48-12 |
100-240 |
4A |
≥85% |
12V DC |
330*18*14.5 |
48W |
SL-60-12 |
100-240 |
5A |
≥85% |
12V DC |
350*18*14.5 |
60W |
SL-72-12 |
100-240 |
6A |
≥85% |
12V DC |
447*18*14.5 |
72W |
工作環(huán)境 (℃) |
工作頻率 (HZ) |
-20-+60 |
50/60Hz |
備注:
① 如未特別說明,所有規(guī)格參數(shù)均在輸入為230VAC,額定負載,25℃環(huán)境溫度下進行測試;
② 波紋和噪音測量方法:使用一條12“雙紋線,同時終端要并聯(lián)0.1uF和47uF的電容,在20MHZ寬帶下進行測量”。
14.產(chǎn)品特點/Product Features:
14.1 國際寬電壓輸入;
14.2 保護種類:短路/過負載/過溫度;
14.3 自熱風冷散熱;
14.4 高效率,長壽命和高信賴性;
14.5 防護等級:IP67;